Image of Geometric calibration of a hyperspectral frame camera with simultaneous determination of sensors misalignment

Text

Geometric calibration of a hyperspectral frame camera with simultaneous determination of sensors misalignment

Lucas D. Santos - Nama Orang; Antonio M.G. Tommaselli - Nama Orang; Adilson Berveglieri - Nama Orang; Nilton N. Imai - Nama Orang; Raquel A. Oliveira - Nama Orang; Eija Honkavaara - Nama Orang;

The recent development of lightweight and relatively low-cost hyperspectral sensors has created new perspectives for remote sensing applications. This study aimed to investigate the geometric calibration of a hyperspectral frame camera based on a tuneable Fabry–Pérot interferometer (FPI) and two sensors. The radiation passes through the optics and then through the FPI, where it is redirected to two sensors using a beam-splitting prism. Previous studies have shown significant variations between the interior orientation parameters for the different bands, both between bands of the same sensor and between different sensors, and that these variations are due to the principle of image acquisition. Discrepancies of tens of pixels were obtained by comparing image coordinates measured in different bands. In this research, it was proposed to calibrate this camera in a static mode with changes in the mathematical calibration model. The restriction of obtaining only one set of exterior orientation parameters by hypercube was applied, adding parameters related to the misalignment between the sensors and parameters of a linear function relating the camera principal distance to the wavelength values. The application of the parameters estimated with this approach reduced the discrepancies between image coordinates measured in different bands to values smaller than one pixel. Using the sensor calibration parameters in the mobile UAV operation in an aerial bundle adjustment reduced the root mean square error (RMSE) on checkpoints by approximately 20% compared to the traditional model in which the interior orientation parameters and lens distortions were calibrated for each band separately. Thus, it was possible to obtain accurate results that make the use of this camera more practical since only one set of calibration parameters for all bands is needed.


Ketersediaan
14621.3678Perpustakaan BIG (Eksternal Harddisk)Tersedia
Informasi Detail
Judul Seri
ISPRS Open Journal of Photogrammetry and Remote Sensing
No. Panggil
621.3678
Penerbit
Amsterdam : Elsevier., 2022
Deskripsi Fisik
16 hlm PDF, 8.291 KB
Bahasa
Inggris
ISBN/ISSN
1872-8235
Klasifikasi
621.3678
Tipe Isi
text
Tipe Media
-
Tipe Pembawa
-
Edisi
Vol.4, April 2022
Subjek
Camera calibration
Hyperspectral imaging
Frame camera
Sensor misalignment
Info Detail Spesifik
-
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Geometric calibration of a hyperspectral frame camera with simultaneous determination of sensors misalignment
    The recent development of lightweight and relatively low-cost hyperspectral sensors has created new perspectives for remote sensing applications. This study aimed to investigate the geometric calibration of a hyperspectral frame camera based on a tuneable Fabry–Pérot interferometer (FPI) and two sensors. The radiation passes through the optics and then through the FPI, where it is redirected to two sensors using a beam-splitting prism. Previous studies have shown significant variations between the interior orientation parameters for the different bands, both between bands of the same sensor and between different sensors, and that these variations are due to the principle of image acquisition. Discrepancies of tens of pixels were obtained by comparing image coordinates measured in different bands. In this research, it was proposed to calibrate this camera in a static mode with changes in the mathematical calibration model. The restriction of obtaining only one set of exterior orientation parameters by hypercube was applied, adding parameters related to the misalignment between the sensors and parameters of a linear function relating the camera principal distance to the wavelength values. The application of the parameters estimated with this approach reduced the discrepancies between image coordinates measured in different bands to values smaller than one pixel. Using the sensor calibration parameters in the mobile UAV operation in an aerial bundle adjustment reduced the root mean square error (RMSE) on checkpoints by approximately 20% compared to the traditional model in which the interior orientation parameters and lens distortions were calibrated for each band separately. Thus, it was possible to obtain accurate results that make the use of this camera more practical since only one set of calibration parameters for all bands is needed.
    Other Resource Link
Komentar

Anda harus masuk sebelum memberikan komentar

PERPUSTAKAAN BIG
  • Informasi
  • Layanan
  • Pustakawan
  • Area Anggota

Tentang Kami

Perpustakaan Badan Informasi Geospasial (BIG) adalah sebuah perpustakaan yang berada di bawah Badan Informasi Geospasial Indonesia. Perpustakaan ini memiliki koleksi yang berkaitan dengan informasi geospasial, termasuk peta, data geospasial, dan literatur terkait. Selengkapnya

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS Kontribusi untuk SLiMS?

© 2025 — Senayan Developer Community

Ditenagai oleh SLiMS
Pilih subjek yang menarik bagi Anda
  • Batas Wilayah
  • Ekologi
  • Fotogrametri
  • Geografi
  • Geologi
  • GIS
  • Ilmu Tanah
  • Kartografi
  • Manajemen Bencana
  • Oceanografi
  • Penginderaan Jauh
  • Peta
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik